Vertical cable tray test alcan b 1c 750 kcmil al a alcan b 3c 750 kcmil al teck90 singleconductor cable 90. Ampacities are based on the 2017 nec and do not reflect any temperature correction or ampacity adjustments that may be required. Versatility resides in this dualrated csa teck 90 ul metal clad mc cable. Learn the principles of ampacity, temperature ratings and derating factors. When sizing conductors, calculations limits wire size to voltage drop and nec ampacity. Question about running teck cable underground to garage an lb is the electrical version of a plumbers elbow or 90 degree fitting with a back cover. Cable ampacity power system software and arc flash hazard. See csa teck 90 armored power and control cable suitable for exposed or concealed wiring in wet or dry locations. Commercial applications for teck cable include apartment buildings and commercial complexes. Interlock armored cables teck90 and mc industrial cables. Determines wire size to meet specific voltage drop limits or calculates voltage drop for a specific conductor run. On the table for 3 phase 60 hz voltage drop single copper conductor teck are curves of voltage drop for single and 3 conductor cables with copper conductors, 3 phase, 60 cycles. Eliminate the need for costly conduit or burial piping. Cable sizing and its effect on thermal and ampacity.
Use of and creating library models for physical cables and ducts. Alcan cable inst allers h ndbook for lc n wire and cables. Maximum ampacity current capacity for wire and cable alte. These interlocking aluminum cables are designed for the demands of mining, pulp and paper, chemical, petroleum and other harsh. Get the multi conductor cable gland that you need when you shop online at one stop buy. Type ggc cables are suitable for use in industrial and light to mediumduty mining applications, heavyduty service as power supply cable, power cable for mobile and portable.
They can be used in cable tray, conduit, and they are approved for direct burial as well. Cme wire and cable 495 horizon drive ne, suite 100, suwanee, georgia 30024. Soow portable electrical cable has applications with portable tools, equipment, and appliances, as well as small motors and associated machinery. Practical power cable ampacity analysis ced engineering. Cable design form to scale input of cable designs is facilitated by a cable expert system.
This teck 90 cable is just one of thousands of options we carry. The nec standard does not provide cable ampacity derating due to bottom cover or correction of the cable ampacity multiplying factors due to the cumulative effects of combinations of tray covers and fireproofing. Teck cable 4 standard design features 5 armoured control 600v 6 teck multiconductor 600v 14 awg 7 12 awg 8 10 awg 9 teck composite 600v 14 awg 10 12 awg 10 teck 1c v 11 teck 2c v 12 teck 3c v teck 4c v 14. As 7another4 mentionned, you must derate the ampacity of the cable, but how. With those modules, the user can evaluate the magnetic flux density at any point on or above the ground of an underground cable installation, determine the positive and zero sequence impedances and admittances for all the cables. Overview of rules implemented in powertools, including nec and recommended industry standard practices. The voltage drop for 4conductor cables, such as in a 3 phase, 4wire grounded neutral system, may be taken from the curve for a 3 conductor cable, where the fourth. Control composite teck cable, 600 volt, 3 conductor, 14 awg control, 4 awg power, stranded bare copper, xlpe, pvc, aia, csa, ft4. Recognized as a costeffective alternative to installation in conduit, teck90. Oct, 2014 as noted, c is applicable to any 2 or 3 conductor cable permitted to be run in cable tray. Teck can be brought up through the slab but i would use a conduit sleeve, etc.
Versatility resides in this dualrated csa teck 90 ul metal clad mc cable, suitabile for use in hazardous environments including dry, damp or wet locations. Calculation of the cable ampacity considers only power cables since control cables. This cable can be used in wet or dry locations up to 90. This table provides you with the allowable ampacity maximum current the cable can carry that you can use with wires in conduit, raceway, cable or directly buried, assuming an ambient temperature of 86f 30c wire size awg copper conductor temp. Teck90 can be used in open and concealed wiring, direct burial, and in hazardous locations. Service entrance wires 5 portable power cords 4 armored cables 3 in stock at store today. Southwire s voltage drop calculator is designed for applications using awg and kcmil sizes only. The thing about being able to use free air ampacity for cables is that it often ends up moot because we are typically limited to the 75.
No you cannot run teck cable in conduit, you have to stick to the table 19 as indicated in article 12100. This free voltage drop calculator estimates the voltage drop of an electrical circuit based on the wire size, distance, and anticipated load current. Csaapproved for open and concealed wiring, direct burial, both dry and wet locations, and for use in class 1 zone 1 and 2, and classes 2 and 3, divisions 1 and 2 hazardous locations. Concrete is not kind to sheathed cable and will corode it over the years. Heat resistant 7 no features 3 weatherproof 2 subscription eligible. The reason is that the heat dissipation for a teck cable in a conduit is unknown, so the ampacity cannot be determined. Helps determine the proper wire size for an electrical circuit based on the voltage. Teck cable is used extensively by the pulp and paper, chemical, mining, petrochemical and manufacturing industries in a broad range of applications, especially where cable may be subjected to mechanical damage and corrosive chemicals. The software examines cable temperature and ampacity in performing analysis of existing systems. The accuracy of the calculation provides increased confidence in the design, upgrading, and analysis projects. In addition, experiment with the resistor and ohms law calculator, or explore hundreds of other calculators addressing math, finance, fitness, health, and more. Used in raceways except cable troughs and ventilated flexible cableways, ceiling fixtures, dry or wet locations and open wiring exposed to weather. Cable ampacity software additional modules allows performing several analyses of interest for cables installations other than thermal analysis.
Southwire company 666 cu seu service entry electrical cable is made with sunlightresistant type xhhw2 or type thhnthwn conductors. Southwire is one of the worlds leading manufacturers of wire and cable, tools, components and assembled solutions. Type ggc cables are suitable for use in industrial and light to mediumduty mining applications, heavyduty service as power supply cable, power cable for mobile and. The user inputs basic parameters cable type, insulation type, voltage rating and conductor area.
C ampacities copper conductors awg or kcmil table 1 table 2 table 1 table 2 free air raceway free air raceway 14 12 10 8 6 4 3 2 1 10 20 3 0 40 250 300 350 400 30 20 35 25 35 25 40 30 50 35 55 40 70 50 80 55 95 65 105 75 125 85. Conductor size, 14, 12, 10, 8, 6, 4, 3, 2, 1, 10, 20, 30, 40, 250, 300, 350. Cable ampacity calculator electrical engineering portal. These cables have the popular thhn stranded inner conductors. Find a variety of armored cables online with competitive teck cable prices.
One stop buy offers different teck cables for sale cut to length for you. Question about running teck cable underground to garage. They consider only temperature limited, current carrying capacity of cables. On the table for 3phase 60 hz voltage drop single copper conductor teck are curves of voltage drop for single and 3conductor cables with copper conductors, 3 phase, 60 cycles. Fault level withstand is calculated and cable size increased if necessary.
As noted, c is applicable to any 2 or 3 conductor cable permitted to be run in cable tray. Aluminum 600v aerial triplex xlp cable is designed for use to supply power, usually from the pole mounted transformer to the users service entrance. General cable s teck90 armored and control cable is factory assembled and tested for use as wiring in all hazardous locations when used with certified hl cable glands per the guidelines of the canadian electrical code. Cablesizer cable sizing calculations to iec and nec standards. The aeic cable specifications are builtin to the program. Armored cables 3 portable power cords 4 service entrance wires 5 conductor gauge. Please consult a qualified electrician or professional engineer to determine the appropriate values for your specific application. Home download center electrical software cable ampacity calculator description this is digital version of the most frequently used ampacity tables that you would find in electrical codes canadas cec and u. With those modules, the user can evaluate the magnetic flux density at any point on or above the ground of an underground cable installation, determine the positive and zero sequence impedances and admittances for all the cables present in an.
Ampacity of 4 conductor cable is based on 3 currentcarrying conductors and 1 neutral. Use of computer programs for calculation of underground cable ampacity software programs usually use neher mcgrath method for the calculation of the cable ampacity. For example, a 10 awg 4c 600 v cables ampacity would need to be derated by 80 percent according to nec 2014 table 310. The cable ampacity analysis software applies to cables in above ground trays, conduits, and air drop. Creating underground duct banks and inair installations. The reason is that the heat dissipation for a teck cable in a conduit is unknown. The count shall be adjusted in accordance with 310. Ampacity rating and recommended configurations for installation of threeconductor copper or threegrouped single conductor copper cables in direct burial types rwu90, ra90, teck 90, acwu90, 0 to 5 kv attention only these configurations are recommended by nexans to obtain satisfactory load sharing and ampactiy. The calculation determines the proper cable sizes to carry specified loads in designing new systems and upgrading power cable installations. These values are based on allowable ampacities of insulated conductors rated up to and including 2000 volts, not more than three currentcarrying conductors in a raceway, cable, or earth, singleinsulated conductor in free air, and an ambient air temperature of 30c 86f. Ampacity is based on ce code part 1, table 2 for 3 conductors in raceway conduit. The voltage drop for 4conductor cables, such as in a 3phase, 4wire grounded neutral system, may be taken from the curve for a 3conductor cable, where the fourth.
169 1125 1359 509 358 903 1146 1328 130 197 278 1161 3 1034 328 585 1427 205 1289 268 347 962 1130 150 1220 1449 1495 92 1458 1128 259 65